9-5 Modbus Communication Register Number List
9
9-5-4 Group A Register List
5807h 5806h
Brake Release Frequency
Setting, 2nd-motor (Forward
side)
AF235 R/W same as AF135 0.01(Hz)
5808h 5807h
Brake Release Current Set-
ting, 2nd-motor (Forward
side)
AF236 R/W same as AF136 0.1(A)
5809h 5808h
Braking Frequency,
2nd-motor (Forward side)
AF237 R/W same as AF137 0.01(Hz)
580Ah 5809h
Brake Wait Time for Release,
2nd-motor (Reverse side)
AF238 R/W same as AF138 0.01(s)
580Bh 580Ah
Brake Wait Time for Accel.,
2nd-motor (Reverse side)
AF239 R/W same as AF139 0.01(s)
580Ch 580Bh
Brake Wait Time for Stopping,
2nd-motor (Reverse side)
AF240 R/W same as AF140 0.01(s)
580Dh 580Ch
Brake Wait Time for Confir-
mation, 2nd-motor (Reverse
side)
AF241 R/W same as AF141 0.01(s)
580Eh 580Dh
Brake Release Frequency
Setting, 2nd-motor (Reverse
side)
AF242 R/W same as AF142 0.01(Hz)
580Fh 580Eh
Brake Release Current Set-
ting, 2nd-motor (Reverse
side)
AF243 R/W same as AF143 0.1(A)
5810h 580Fh
Braking Frequency,
2nd-motor (Reverse side)
AF244 R/W same as AF144 0.01(Hz)
5816h 5815h
Brake open delay time,
2nd-motor
AF250 R/W same as AF150 0.01(s)
5817h 5816h
Brake close delay time,
2nd-motor
AF251 R/W same as AF151 0.01(s)
5818h 5817h
Brake answer back check
time, 2nd-motor
AF252 R/W same as AF152 0.01(s)
5819h 5818h
Servo lock/ DC injection time
at start, 2nd-motor
AF253 R/W same as AF153 0.01(s)
581Ah 5819h
Servo lock/ DC injection time
at stop, 2nd-motor
AF254 R/W same as AF154 0.01(s)
5849h 5848h Jump frequency 1, 2nd-motor AG201 R/W same as AG101 0.01(Hz)
584Ah 5849h
Jump frequency width 1,
2nd-motor
AG202 R/W same as AG102 0.01(Hz)
584Bh 584Ah Jump frequency 2, 2nd-motor AG203 R/W same as AG103 0.01(Hz)
584Ch 584Bh
Jump frequency width 2,
2nd-motor
AG204 R/W same as AG104 0.01(Hz)
584Dh 584Ch Jump frequency 3, 2nd-motor AG205 R/W same as AG105 0.01(Hz)
584Eh 584Dh
Jump frequency width 3,
2nd-motor
AG206 R/W same as AG106 0.01(Hz)
5852h 5851h
Acceleration stop frequency
setting, 2nd-motor
AG210 R/W same as AG110 0.01(Hz)
5853h 5852h
Acceleration stop time setting,
2nd-motor
AG211 R/W same as AG111 0.1(s)
5854h 5853h
Deceleration stop frequency
setting, 2nd-motor
A
G212 R/W same as AG112 0.01(Hz)
5854h 5853h
Deceleration stop time set-
ting, 2nd-motor
AG213 R/W same as AG113 0.1(s)
*1. Cannot be selected if [Ub-03] load type selection is 01 (LD) or 00 (VLD).
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution