9 Communications Functions
9 - 76
High-function General-purpose Inverter RX2 Series User’s Manual
3798h 3797h
Output relay [AL] on-delay
time
CC-32 R/W 0 to 10000 0.01(s)
3799h 3798h
Output relay [AL] off-delay
time
CC-33 R/W 0 to 10000 0.01(s)
37A0h 379Fh
Logical calculation target 1
selection of LOG1
CC-40 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37A1h 37A0h
Logical calculation target 2
selection of LOG1
CC-41 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37A2h 37A1h
Logical calculation symbol
selection of LOG1
CC-42 R/W
00:AND
01:OR
02:XOR
-
37A3h 37A2h
Logical calculation target 1
selection of LOG2
CC-43 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37A4h 37A3h
Logical calculation target 2
selection of LOG2
CC-44 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37A5h 37A4h
Logical calculation symbol
selection of LOG2
CC-45 R/W
00:AND
01:OR
02:XOR
-
37A6h 37A5h
Logical calculation target 1
selection of LOG3
CC-46 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37A7h 37A6h
Logical calculation target 2
selection of LOG3
CC-47 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37A8h 37A7h
Logical calculation symbol
selection of LOG3
CC-48 R/W
00:AND
01:OR
02:XOR
-
37A9h 37A8h
Logical calculation target 1
selection of LOG4
CC-49 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37Aah 37A9h
Logical calculation target 2
selection of LOG4
CC-50 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37Abh 37AAh
Log
ical calcu
lation symbol
selection of LOG4
CC-51 R/W
00:AND
01:OR
02:XOR
-
37Ach 37ABh
Logical calculation target 1
selection of LOG5
CC-52 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37Adh 37ACh
Logical calculation target 2
selection of LOG5
CC-53 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
37Aeh 37ADh
Logical calculation symbol
selection of LOG5
CC-54 R/W
00:AND
01:OR
02:XOR
-
37Afh 37AEh
Logical calculation target 1
selection of LOG6
CC-55 R/W
See <List of output terminal func-
tions> 062: LOG1 to 068: LOG7
cannot be selected.
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution