Appendices A Technical Information
A - 14
High-function General-purpose Inverter RX2 Series User’s Manual
A105 OI start selection Cb-17 For Ai2
A111 O2 start Cb-23 For Ai3
A112 O2 end Cb-24 For Ai3
A113 O2 start ratio Cb-25 For Ai3
A114 O2 end ratio Cb-26 For Ai3
A131 Acceleration curve constant AC-05
A132 Deceleration curve constant AC-06
A141 Operation frequency selection 1 AA101
Integrated into main speed/auxiliary
speed command.
Addition of individual settings for sec-
ond control
A142 Arithmetic operation frequency selection 2 AA102
Integrated into main speed/auxiliary
speed command.
Addition of individual settings for sec-
ond control
A143 Arithmetic operation operator selection AA105
Addition of individual settings for sec-
ond control
A145 Additional frequency setting AA106
Addition of individual settings for sec-
ond control
A146 Additional frequency sign selection
You can change the sign by setting
AA106 with ±.
A150 Curvature 1 for EL-S-shaped acceleration AC-08
A151 Curvature 2 for EL-S-shaped acceleration AC-09
A152 Curvature 1 for EL-S-shaped deceleration AC-10
A153 Curvature 2 for EL-S-shaped deceleration AC-11
b001
Selection of instantaneous power failure/
undervoltage restart
bb-24
Specify b001=00 (trip) with retry count
(instantaneous power failure
[bb-20]/undervoltage [bb-21]) with
zero.
b002 Allowable instantaneous power failure time bb-25
b003
Retry stand-by time for instantaneous
power failure and insufficient voltage
bb-26
b004
Instantaneous power failure/undervoltage
tripping selection during stop
bb-27
b005
Selection of instantaneous power failure
retry count
bb-20 0: trip, 255: infinite
b006 Input phase loss selection bb-65
b007 f matching lower limit frequency setting bb-42
b008 Trip retry selection bb-28
Specify b008=00 (trip) with retry count
(overvoltage [bb-22]/undercurrent
[bb-23]) with zero.
b009 Selection of undervoltage retry count bb-21 0: trip, 255: infinite
b010
Selection of overvoltage/overcurrent retry
count
bb-22
bb-23
Specify overvoltage [bb-22] and over-
current [bb-23] individually.
b011 Trip retry standby time bb-29
b012 First electronic thermal level bC110
b212 Second electronic thermal level bC210
b312 Third electronic thermal level Abolition of third control
b013
Selection of first electronic thermal charac-
teristics
bC111
b213
Selection of second electronic thermal
characteristics
bC211
3G3RX-series V1 3G3RX2-series
Remarks
Display
code
Function name New code