EasyManua.ls Logo

Omron RX2 Series - Page 821

Omron RX2 Series
920 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A - 13
Appendices A Technical Information
High-function General-purpose Inverter RX2 Series User’s Manual
A-2 Parameter Comparison
A
A064 Jump frequency width 1 AG102
Addition of individual settings for sec-
ond control
A065 Jump frequency 2 AG103
Addition of individual settings for sec-
ond control
A066 Jump frequency width 2 AG104
Addition of individual settings for sec-
ond control
A067 Jump frequency 3 AG105
Addition of individual settings for sec-
ond control
A068 Jump frequency width 3 AG106
Addition of individual settings for sec-
ond control
A069 Acceleration stop frequency AG110
Addition of individual settings for sec-
ond control
A070 Acceleration stop time AG111
Addition of individual settings for sec-
ond control
A071 PID selection AH-01
A072 PID P gain AH-61
A073 PID I gain AH-62
A074 PID D gain AH-63
A075 PID scale Configured with AH-04 - AH-06
A076 PID feedback selection AH-51
A077 PID deviation reverse output AH-02
A078 PID changeable range AH-71
A079 PID feed forward selection AH-70
A081 AVR selection bA146
Second control extension
* 00→00, 01→01, 02→02
The same values are used for equiva-
lent operations.
A082 Motor incoming voltage selection Hb106/Hd106
Configured with Hb106 (IM)/Hd106
(SM/PMM).
A085 Operation mode selection Hb145
Addition of individual settings for sec-
ond control
A086
Energy-saving response/accuracy adjust-
ment
Hb146
Addition of individual settings for sec-
ond control
A092 First acceleration time 2 AC124
A292 Second acceleration time 2 AC224
A392 Second acceleration time 3 Abolition of third control
A093 First deceleration time 2 AC126
A293 Second deceleration time 2 AC226
A393 Second deceleration time 3 Abolition of third control
A094
First 2-step acceleration/deceleration selec-
tion
AC115
A294
Second 2-step acceleration/deceleration
selection
AC215
A095 First 2-stage acceleration frequency AC116
A295 Second 2-stage acceleration frequency AC216
A096 First 2-stage deceleration frequency AC117
A296 Second 2-stage deceleration frequency AC217
A097 Acceleration pattern selection AC-03
A098 Deceleration pattern selection AC-04
A101 OI start Cb-13 For Ai2
A102 OI end Cb-14 For Ai2
A103 OI start ratio Cb-15 For Ai2
A104 OI end ratio Cb-16 For Ai2
3G3RX-series V1 3G3RX2-series
Remarks
Display
code
Function name New code

Table of Contents

Related product manuals