A - 19
Appendices A Technical Information
High-function General-purpose Inverter RX2 Series User’s Manual
A-2 Parameter Comparison
A
C042 Acceleration reaching frequency CE-10
C043 Deceleration reaching frequency CE-11
C044 PID excessive deviation level AH-72
C045 Acceleration reaching frequency 2 CE-12
C046 Deceleration reaching frequency 2 CE-13
C052 Feedback comparison signal OFF level AH-73
C053 Feedback comparison signal ON level AH-74
C055 Overtorque level (normal rotation powered) CE120
Addition of individual settings for sec-
ond control
C056
Overtorque level (reverse rotation regener-
ative)
CE121
Addition of individual settings for sec-
ond control
C057 Overtorque level (reverse rotation powered) CE122
Addition of individual settings for sec-
ond control
C058
Overtorque level (normal rotation regenera-
tive)
CE123
Addition of individual settings for sec-
ond control
C061 Thermal warning level CE-30
C062 Alarm code selection
This function is enabled when an
alarm code (084-087) is set to an
input terminal.
C063 0Hz detection level CE-33
C064 Cooling fin overheat advance notice level CE-34
C071
Communication transmission speed selec-
tion
CF-01
C072 Communication station number selection CF-02
C073 Communication bit length selection
Abolished due to Modbus communi-
cation
C074 Communication parity selection CF-03
C075 Communication stop bit selection CF-04
C076 Communication error selection CF-05
C077 Communication trip time CF-06
C078 Stop waiting time CF-07
C079 Communication method selection
Abolished due to Modbus communi-
cation
C081 O adjustment Adjusted with Cb-30 or Cb-31
C082 OI adjustment Adjusted with Cb-32 or Cb-33
C083 O2 adjustment Adjusted with Cb-34 or Cb-35
C085 Thermistor adjustment Cb-41
C091 Debug mode selection UC-01
C101 UP/DWN memory selection CA-61
C102 Reset selection CA-72
C103 Reset f matching selection bb-41
C105 FM gain setting Cd-14
C106 AM gain setting Cd-24
C107 AMI gain setting Cd-34
C109 AM bias setting Cd-23
C110 AMI bias setting Cd-33
C111 Overload advance notice level 2 CE107
C121 O zero adjustment Cb-30/Cb-31 Adjusted with Cb-30 or Cb-31
C122 OI zero adjustment Cb-32/Cb-33 Adjusted with Cb-32 or Cb-33
C123 O2 zero adjustment Cb-34/Cb-35 Adjusted with Cb-34 or Cb-35
C130 Output 11 on-delay time CC-20
C131 Output 11 off-delay time CC-21
3G3RX-series V1 3G3RX2-series
Remarks
Display
code
Function name New code