lower the number, the more responsive the receiver will be to acknowledge
the bursts. The default value is optimized for an indoor antenna. A higher
value can be used for outdoor antenna installations (not typical). A value lower
than (40) is not recommended.
3.
Assign the STL 0 reference a reference priority by navigating to MANAGEMENT >
OTHER: Reference Priority.
4.
In the Configure Reference Priorities panel, click the + icon in the upper right
corner. The Add Reference window will open.
5.
Select a Priority Level:
a.
If STL is to be used as a backup to GPS: Select a Priority Level of 2.
b.
If STL is the only reference: Select a Priority Level of 1.
For Time and PPS, select STL 0. Click Submit.
6.
Verify your settings in the Reference Priority table, and ensure that the new ref-
erence is Enabled.
Reviewing the STL Status
Validity Status
To check or monitor the validity of the STL reference:
1.
Navigate to INTERFACES > REFERENCES.
2.
In the References status panel, under STL 0, check the status indicator light:
Detailed Status
SecureSync 2400 User Manual 483