DOB 1300-1556| X3-45 Commuter PA-1648 Maintenance Manual Section 23 revised Nov 2021
qualified fire protection equipment company
familiar with Kidde equipment if:
o If a pit, gouge, or cut exceeds a depth of
0.08 inches.
o If the depth of a dent exceeds 0.25
inches or one tenth of the average di-
ameter of the dent.
o If corrosion exceeds a depth of 0.05
inches or a coverage area larger than
15% of the extinguisher’s outer surface.
5.3 SYSTEM TESTING
MAINTENANCE
Perform a fire system test and service the
extinguisher ac
cording to the Lubrication &
Servicing schedule.
•
To perform a complete fire system test,
refer to Kidde R10723 document – “Kidde
Generic AFSS Datalogger System
Checkout Procedure”
(Use Kidde Dual Spectrum System Test Set
- P/N 420871-2).
5.4 SIX YEARS & TWELVE YEARS
MAINTENANCE
MAINTENANCE
EVERY SIX YEARS
If the date of manufacture of the extinguisher is
past the 6 year mark, Replace the system’s fire
extinguishe
r with a new or refurbished
extinguisher.
The system’s fire extinguisher
can be refurbished by a qualified fire protection
equipment company familiar with Kidde CGV
equipment.
EVERY TWELVE YEARS
If the date of manufacture of the extinguisher is
past the 12 year mark, replace the system’s fire
extinguisher with a new or refurbished
extinguisher. A fire extinguisher with a date of
manufacture past the 12 year mark will need to
be hydrostatically tested by a qualified fire
protection equipment company familia
Kidde equipment.
NOTE
The date of manufacture of the extinguisher
can be found stamped
either (MM/YY) or
(YYYY/MM) on the top neck of the cylinder.
This is the date that should be used to
determine the 6 or 12 year service interval
date.
CAUTION
The AFSS extinguisher will not function as
intended if oriented incorrectly. Refer to labels
on the extinguisher bottle or the “Operation &
Maintenance Manual’’.
6. WHEELCHAIR LIFT CASSETTE
INSTALLATION
WARNING
For better stability, keep the platform at
minimum height when moving.
WARNING
Never deploy the platform from enclosure
while standing on the telescopic legs.
WARNING
Telescopic legs were designed to support and
move the platform only, do not use as a work
table.
WARNING
Before moving platform, make sure that floor
is level and free of obstacles.
Install four lifting jacks on the wheelchair lift
cassette.
NOTE
There are two telescopic legs for each
platform side. The proper side is indicated
onto the telescopic leg.