EasyManua.ls Logo

R&S SMA100B - Page 579

R&S SMA100B
822 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
SMA100B
579User Manual 1178.3834.02 ─ 09
Manual operation: See "State" on page 87
[:SOURce<hw>]:PM<ch>:SOURce <Source>
Selects the modulation source for phase modulation signal.
Suffix:
PM<ch>
.
1|2
Sets the modulation signal channel.
Parameters:
<Source> LF1 | LF2 | NOISe | EXT1 | EXT2 | INTernal | EXTernal
LF1|LF2
Uses an internally generated LF signal.
EXT1|EXT2
Uses an externally supplied LF signal.
NOISe
Uses the internally generated noise signal.
INTernal
Uses the internally generated signal of LF1.
EXTernal
Uses an external LF signal (EXT1).
*RST:
LF1 <PM1>; LF2 <PM2>
Example: See Example "Performing phase modulation" on page 577.
Manual operation: See "Source" on page 87
[:SOURce<hw>]:PM:MODE <Mode>
Selects the mode for the phase modulation.
Parameters:
<Mode> HBANdwidth | HDEViation | LNOise
HBANdwidth
Sets the maximum available bandwidth.
HDEViation
Sets the maximum range for ΦM deviation.
LNOise
Selects a phase modulation mode with phase noise and spuri-
ous characteristics close to CW mode.
*RST: HBANdwidth
Example: See Example "Performing phase modulation" on page 577.
Manual operation: See "Mode" on page 90
SOURce subsystem