Remote control commands
R&S
®
SMA100B
595User Manual 1178.3834.02 ─ 09
:SOURce1:ILS:STATe 1
Example: Configure and generate an ILS localizer signal
:SOURce1:ILS:PRESet
// Configure ILS localizer general settings.
:SOURce1:ILS:TYPE LOC
:SOURce1:ILS:LOCalizer:FREQuency:MODE USER
:SOURce1:ILS:LOCalizer:FREQuency 108100000
:SOURce1:ILS:LOCalizer:FREQuency:SYNChronize 1
:SOURce1:ILS:GS:FREQuency?
// 108100000
:SOURce1:ILS:LOCalizer:FREQuency:MODE ICAO
:SOURce1:ILS:LOCalizer:ICAO:CHANnel CH26Y
:SOURce1:ILS:GS:ICAO:CHANnel?
// CH26Y
:SOURce1:ILS:GS:FREQuency?
// 108950000
:SOURce1:ILS:LOCalizer:SOURce?
// INT
// Configure ILS localizer signal settings.
:SOURce1:ILS:LOCalizer:MODE NORM
:SOURce1:ILS:LOCalizer:DDM:POLarity P90_150
:SOURce1:ILS:LOCalizer:LLOBe:FREQuency 90
:SOURce1:ILS:LOCalizer:RLOBe:FREQuency 150
:SOURce1:ILS:LOCalizer:PHASe 0
// Configure ILS localizer amplitude settings.
:SOURce1:ILS:LOCalizer:DDM:DIRection LEFT
:SOURce1:ILS:LOCalizer:SDM 40
:SOURce1:ILS:LOCalizer:DDM:COUPling FIX
:SOURce1:ILS:LOCalizer:DDM:STEP DEC
:SOURce1:ILS:LOCalizer:DDM:CURRent 0
:SOURce1:ILS:LOCalizer:DDM:DEPTh 0
:SOURce1:ILS:LOCalizer:DDM:LOGarithmic 0
:SOURce1:ILS:LOCalizer:DDM:PCT 0
// Configure ILS localizer COM/ID settings.
:SOURce1:ILS:LOCalizer:COMid:CODE "MUC"
:SOURce1:ILS:LOCalizer:COMid:PERiod 9
:SOURce1:ILS:LOCalizer:COMid:FREQuency 1020
:SOURce1:ILS:LOCalizer:COMid:DEPTh 10
:SOURce1:ILS:LOCalizer:COMid:TSCHema USER
:SOURce1:ILS:LOCalizer:COMid:DOT 0.11
:SOURce1:ILS:LOCalizer:COMid:DASH 0.29
:SOURce1:ILS:LOCalizer:COMid:SYMBol 0.11
:SOURce1:ILS:LOCalizer:COMid:LETTer 0.29
:SOURce1:ILS:LOCalizer:COMid:STATe 1
SOURce subsystem