Remote control commands
R&S
®
SMA100B
696User Manual 1178.3834.02 ─ 09
DER10M|DER100M
Sets the output reference frequency to 10 MHz or 100 MHz.
The reference frequency is derived from the internal reference
frequency.
LOOPthrough
This option is unavailable for
ROSCillator:EXTernal:FREQuency 1GHZ. Forwards the
input reference frequency to the reference frequency output.
*RST: n.a. (factory preset: DER10M)
Example: See Example "Configuring the reference oscillator" on page 692.
Manual operation: See "Reference Output/1 GHz Reference Output" on page 298
[:SOURce]:ROSCillator:OUTPut:ALTernate:FREQuency:MODE
<OutpFreqMode>
Sets the output reference frequency.
Parameters:
<OutpFreqMode> LOOPthrough | DER1G | OFF
OFF
Disables the output.
DER1G
Sets the output reference frequency to 1 GHz.
The reference frequency is derived from the internal reference
frequency.
LOOPthrough
If [:SOURce]:ROSCillator:EXTernal:FREQuency 1GHZ,
forwards the input reference frequency to the reference fre-
quency output.
*RST:
n.a. (factory preset: OFF)
Example: See Example "Configuring the reference oscillator" on page 692.
Manual operation: See "Reference Output/1 GHz Reference Output" on page 298
[:SOURce]:ROSCillator[:INTernal]:ADJust:VALue <Value>
Specifies the frequency correction value (adjustment value).
Parameters:
<Value> integer
*RST: 0
Example: See [:SOURce]:ROSCillator[:INTernal]:ADJust[:
STATe] on page 697
Manual operation: See "Adjustment Value" on page 300