17 Printing  
17.4
17.
281
GC-2010 Plus
17.4Event No.
Many parameters are printed with event No. The list below shows the correspondence of event
No. to functions.
Q Event No. list
No. Meaning of “Event xx” (Example: Event 1) Meaning of “Event-xx” (Example: Event -1)
0
Reverses contact status of Events 1 to 16 and
Events 91 to 96.
Opens contact of Events 1 to 16 and switches
contact of events 91 to 96 to N/C type (normal).
1
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
2
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
3
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
4
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
5
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
6
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
7
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
8
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
9
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
10
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
11
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
12
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
13
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
14
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
15
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
16
Turns on contact of one contact in one circuit
(option PRG).
Turns off contact of one contact in one circuit
(option PRG).
51 Performs zero adjustment of DET #1. Frees zero adjustment of DET #1.
52 Performs zero adjustment of DET #2. Frees zero adjustment of DET #2.
53 Performs zero adjustment of DET #3. Frees zero adjustment of DET #3.
54 Performs zero adjustment of DET #4. Frees zero adjustment of DET #4.
61
Turns on CAR1 gas saver.
Sets split ratio to value of CAR1 gas saver split
ratio 1.
Turns off CAR1 gas saver.
Returns split ratio to value of analysis
parameter.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shimadzu GC-2010 Plus and is the answer not in the manual?

Shimadzu GC-2010 Plus Specifications

General IconGeneral
TypeGas Chromatograph
ModelGC-2010 Plus
ManufacturerShimadzu
Maximum Temperature Ramp Rate120 °C/min
Detector OptionsFID, TCD, ECD, FPD, NPD, MS
Electronic Flow Control (EFC)Yes
Data Sampling RateUp to 250 Hz
Column Oven Temperature RangeAmbient +5°C to 450°C
Maximum Oven Heating Rate120 °C/min
Injection PortSplit/Splitless, PTV
DisplayLCD