class
PN
1)
(hex)
Explanation of the message class according to PROFIdrive -
cause and remedy.
10 9009 Safety monitoring channel has identified an error
A safe operation monitoring function has detected an error.
11 900A Actual position value / actual speed value incorrect or not available
An illegal signal state has been detected while evaluating the encoder signals
(track signals, zero marks, absolute values…).
Check the encoder / state of the encoder signals.
Observe the maximum permissible frequencies.
12 900B Internal (DRIVE-CLiQ) communication error
The internal communication between the SINAMICS components is faulted
or interrupted. Check the DRIVE-CLiQ wiring.
Ensure an EMC-compliant design.
13 900C Infeed fault
The infeed is faulted or has failed.
Check the infeed and its environment (line supply, filters, reactors,
fuses…).
Check the infeed control.
14 900D Braking controller / Braking Module faulted
The internal or external Braking Module is faulted or overloaded (tempera‐
ture).
Check the connection/state of the Braking Module.
Comply with the permissible number of braking operations and their
duration.
15 900E Line filter faulted
The line filter monitoring has identified an excessively high temperature or
other inadmissible state.
Check the temperature / temperature monitoring.
Check the configuration to ensure that it is permissible (filter type, infeed,
thresholds).
16 900F External measured value / signal state outside of the permissible range
A measured value / signal state read in via the input area (digital/analog/tem‐
perature) has assumed an inadmissible value/state.
Identify and check the relevant signal.
Check the set thresholds.
17 9010 Application / technology function faulted
The application / technological function has exceeded a (set) limit (position,
velocity, torque…).
Identify and check the relevant limit.
Check the setpoint specification of the higher-level controller.