EasyManuals Logo

Tektronix DSA70000/B Series Programmer's Manual

Tektronix DSA70000/B Series
733 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
Commands Listed in Alphabetical Order
Group
Cursor
Syntax
CURSor:HBArs:DELTa?
Related Commands
CURSor:HBArs:UNIts?
Returns
A oating point value with an exponent.
Examples
CURSOR:HBARS:DELTA? might return :CURSOR:HBA RS:DELTA 5.0800E+00,
indicating that the voltage difference between the two cursors is 5.08 V.
CURSor:HBArs:POSITION<x>
This command sets or queries the horizontal bar cursor position relative to ground,
which is expressed in vertical units (usually volts). The cursor is specied by x,
which can be 1 or 2. This command is the equivalent to selecting Cursor Position
from the Cursors menu, selecting the H Bars Cursor Type, and then viewing
or editing the desired cursor position.
Group
Cursor
Syntax
CURSor:HBArs:POSITION<x> <NR3>
CURSor:HBArs:POSITION<x>?
Related Commands
CURSor:FUNCtion
Arguments
<NR3> species the cursor position relative to ground.
Examples
CURSOR:HBARS:POSITION1 25.0E-3 positions Cursor 1 of the horizontal
cursors at 25 mV.
CURSOR:HBARS:POSITION2? might return :CURSOR:HBAR S:POSITION2
-64.0000E-03
, indicating that Cursor 2 of the horizontal bar cursors is at -64 mV.
CURSor:HBArs:UNIts? (Query Only)
This query-only command returns the units for the horizontal bar cursors.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-133

Table of Contents

Other manuals for Tektronix DSA70000/B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DSA70000/B Series and is the answer not in the manual?

Tektronix DSA70000/B Series Specifications

General IconGeneral
BrandTektronix
ModelDSA70000/B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals