Commands Listed in Alphabetical Order
10.0000;MID1 5
0.0000;MID2 50.0000;:MEASUREMENT:MEAS1:MET HOD
HISTOGRAM;NOISE HIGH.
MEASUrement:MEAS<x>:COUNt? (Query Only)
This query-only command returns the number of values accumulated for this
measurement since the last statistical rese t. Some values may have been ignored
because they generated an error. Measurements are specified by x, which ranges
from 1 through 8.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:COUNt ?
Examples
MEASUREMENT:MEAS3:COUNT? might return : MEASUREMENT:MEAS3:COUNT
3.247000000E+03.
MEASUrement:MEAS<x>:DELay? (Query Only)
This query-only command returns the delay measurement parameters for the
measurement specified by <x>, which ranges from 1 through 8. Measurement
parameters are presented in the following order: Edge1, Edge2, and Direction.
This query command is equivalent to selecting Time from the Measure menu,
choosing Delay and viewing the Delay Edge and Search Direction settings.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:DELay ?
Examples
MEASUREMENT:MEAS3? might return :MEASUREMEN T:MEAS3:DELAY:EDGE1
RISE;EDGE2 RISE;DIRECTION FORWARDS
.
MEASUrement:MEAS<x>:DELay:DIREction
This command sets or queries the starting point and direction that
determines the delay “to” edge when taking a delay measurement. Use the
MEASUrement:MEAS<x>:SOUrce<x> command to specify the waveform. This
command is equivalent to selecting Time from the Measure menu, choosing Delay
from the drop-down list and then clicking the desired Search Direction setting.
Measurements are specified by x, which ranges from 1 through 8.
2-384 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual