Commands Listed in Alphabetical Order
LIMit? (Query
Only)
This query-only command returns all settings for the Limit commands.
NOTE. The command works only if the LT Limit Test option is enabled.
Group
Limit Test
Syntax
LIMit?
Examples
LIMIT? might return :LIMIT:BEEP 0;COMPARE:CH1 NONE;CH2
NONE;CH3 NONE;CH4 NONE ;REF1 NONE;REF2 NONE;R EF3
NONE;REF4 NONE;MATH1 N ONE;MATH2 NONE;MATH3 N ONE;MATH4
NONE;:LIMIT:HARDCOPY 0;STATE 0;TEMPLATE:DESTINATION
REF1;SOURCE CH2;TOLERANCE:HORIZONTAL 40.0000E-3;VERTICAL
40.0000E-3;:LIMIT:SRQ 0;STOPONVIOLA TION 0;SAVEWFM
0;SAVEWFM:FILENAME "C:/TekScope/wav eforms/";:LIMIT: LOG
0;EMAIL 0;HIGHLIGHTHITS 1;LOCK 1
.
LIMit:BEEP
This command causes the instrument to beep when the waveform data exceeds the
limits set in the limit test (LIMit:STATE must be on).
NOTE. The command works only if the LT Limit Test option is enabled.
Group
Limit Test
Syntax
LIMit:BEEP {OFF|ON|<NR1>}
LIMit:BEEP?
Related Commands
LIMit:STATE
Arguments
OFF argument disables the beep.
ON argument enables the beep.
<NR1>
A 0 disables the beep, any other value enables the beep.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-265