Commands Listed in Alphabetical Order
Group
Measurement
Syntax
MEASUrement:IMMed:DELay:E DGE2 {FALL|RISe}
MEASUrement:IMMed:DELay:E DGE2?
Related Commands
MEASUrement:IMMed:SOUrce<x>
Arguments
FALL specifies the falling edge.
RISe specifies the rising edge.
Examples
MEASUREMENT:IMMED:DELAY:E DGE2 RISE specifies that the rising edge be
used for the immediate delay measurement.
MEASUREMENT:IMMED:DELAY:E DGE2? might return
:MEASUREMENT:IMMED:DELAY: EDGE2 FALL, indicating that the falling edge or
negative edge of the waveform is used for the immediate delay measurement.
MEASUrement:IMMed:METHod
This command specifies or queries the method used to calculate the 0% and 100%
reference level for immediate measurements.
Group
Measurement
Syntax
MEASUrement:IMMed:METHod {HIStogram|MINMa x|MEAN}
MEASUrement:IMMed:METHod?
Arguments
HIStogram sets the high and low waveform levels statistically using a histogram
algorithm.
MINMax sets the high and low waveform levels to MAX and MIN, respec tively.
MEAN sets the high and low waveform levels to their mean.
Examples
MEASUREMENT:IMMED:METHOD HISTOGRAM specifi es that the high and low
reference levels are set statistically.
MEASUREMENT:IMMED:METHOD? might return :MEASUREMENT:IMMED:METHOD
MINMAX
, indicating that the reference levels are set to MIN and MAX for
immediate m easurements.
2-370 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual