Commands Listed in Alphabetical Order
OFF turns off th
e eight bit interpolation mode.
Trial
Examples
ACQUIRE:INTERPEIGHTBIT ON sets the interpolation sampling mode ON.
ACQUIRE:INTERPEIGHTBIT? might r eturn :ACQUIRE:INTERPEIGH TBIT
AUTO
indicating the interpolation sampling mode is set to AUTO.
ACQuire:MODe
This command sets or queries the ac
quisition mode of the instrument.
This affects all live waveforms. This command is equivalent to selecting
Horizontal/Acquisition from the Horiz/Acq menu, and then choosing the desired
mode from the Acquisition Mode group box.
Waveforms are the displayed data point v alues taken from acquisition intervals.
Each acquisition interval represents a time duration set by the horizontal scale
(time per division). The instrument sampling system always samples at the
maximum rate and so an acquisition interval may include more than one sample.
The acquisition mode (which you set using this ACQuire:MODe command)
determines how the nal value of the acquisition interval is generated from the
many data samples.
Group
Acquisition
Syntax
ACQuire:MODe
{SAMple|PEAKdetect|HIRes| AVErage|WFMDB|ENVelope}
ACQuire:MODe?
Related Commands
ACQuire:NUMAV g, CURVe
Arguments
SAMple species that the displayed data point value is the rst sampled value
that is taken during the acquisition interval. In sample mode, all waveform data
has 8 bits of precision. You can request 16 bit data with a CURVe query but the
lower-order 8 bits of data will be zero.
SAMple is the default mode.
PEAKdetect species the display of high-low range of the samples taken from a
single waveform acquisition. The high-low range is displayed as a vertical column
that extends from the highest to the lowest value sampled during the acquisition
interval.
PEAKdetect mode can reveal the presence o f aliasing or narrow spikes.
HIRes species Hi Res mode where the displayed data point value is the
average of all the samples taken during the acquisition interval. This is a form
of averaging, where the average comes from a single waveform acquisition. The
2-76 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual

Table of Contents

Other manuals for Tektronix DSA70000/B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DSA70000/B Series and is the answer not in the manual?

Tektronix DSA70000/B Series Specifications

General IconGeneral
BrandTektronix
ModelDSA70000/B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals