Commands Listed in Alphabetical Order
TRIGger:A:SE
RIAL:CLOCk:POLarity
This command sets or queries the serial clock polarity.
Group
Low Speed Serial Trigger
Syntax
TRIGger:A:SERIAL:CLOCk:POL arity {RISe|FALL}
TRIGger:A:SERIAL:CLOCk:POL arity?
Arguments
RISe species to trigger on the rising or positive edge of a signal.
FALL species to trigger on the falling or negative edge of a signal.
Examples
TRIGGER:A:SERIAL:CLOCK:POL ARITY RISE sets the clock polarity to rise.
TRIGGER:A:SERIAL:CLOCK:POL ARITY? might return
:TRIGGER:A:SERIAL:CLOCK:PO LARITY FALL, indicating that the
clock polarity is set to fall.
DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual 2-581