Commands Listed in Alphabetical Order
The Histogram:
DATa? query corresponds to the Histogram Data (CSV) controls
included in the instrument user interface. To nd these controls, select either Edit
> Copy > Setup > Measurements tab or the File > Save As > Histogram button.
This command returns only histogram data values separated by commas on a
single line. The CSV le created by the user interface actions indicated above,
writes out a line for each histogram data point, and contains the time relative to
the trigger, a comma, and the histogram va lue.
Group
Histogram
Syntax
HIStogram:DATa?
Related Commands
HIStogram:BOX, HIStogram:BOXPcnt, HIStogram:COUNt,
HIStogram:DISplay, HIStogram:FUNCtion, HIStogram:MODe, HIStogram:SIZe,
HIStogram:SOUrce, HIStogram:STATE
Examples
HISTOGRAM:DATA? might return : HISTOGRAM:DATA
0,0,0,0,0,0,0,0,0,0,0,0,0 ,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0 ,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,1245,933,903, 1003,838,782,764,697,
687,620,582,566,530,595,5 57,552,518,524,606,
503,526,470,498,554,534,4 87,546,548,504,554,
513,566,639,508,643,704,6 62,769,785,806,922,
960,1153,1336,1478,1960,4 515,17598,52184,
67040,50417,12885,4104,23 82,1866,1699,1428,
1288,1271,1140,975,1024,8 94,841,841,678,841,
804,685,713,746,729,644,6 40,787,768,668,671,
661,745,755,692,882,772,8 02,862,770,854,799,
969,1102,1080,1040,1272,1 329,1394,1760,1428,
2418,3313,4475,0,0,0,0,0, 0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0,0 ,0,0,0,0,0,0,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0
.
HIStogram:DISplay
This command sets the scaling of the histogram data display to be the count of
each histogram bin or the log of that c ount. The default scaling is Linear.
The query form of this command returns either the histogram display scaling or
the display status “off.”
This command is equivalent to selecting Waveform Histogram from the Measure
menu, and then selecting Linear o r Log in the Histogram Scaling group.
2-234 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual

Table of Contents

Other manuals for Tektronix DSA70000/B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DSA70000/B Series and is the answer not in the manual?

Tektronix DSA70000/B Series Specifications

General IconGeneral
BrandTektronix
ModelDSA70000/B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals