Commands Listed in Alphabetical Order
Group
Measurement
Syntax
MEASUrement:MEAS<x>:STDde v?
Examples
MEASUREMENT:MEAS1:STDDEV? might return :MEASUREMENT:MEAS1:STDDEV
21.0E-12.
MEASUrement:MEAS<x>:TYPe
This command sets or queries the measurement type dened for the specied
measurement slot. The measurement slot is specied by x, which ranges from 1
through 8. This command is equivalent to selecting Measurement Setup from the
Measure menu and then choosing the desired measurement type.
Group
Measurement
Syntax
ME
ASUrement:MEAS<x>:TYPe {AMPlitude|AREa|
BURst|CARea|CMEan|CRMs|DE Lay|DISTDUty|
EXTINCTDB|EXTINCTPCT|EXTI NCTRATIO|EYEHeight|
EY
EWIdth|FALL|FREQuency|HIGH| HITs|LOW|
MAXimum|MEAN|MEDian|MINIm um|NCROss|NDUty|
NOVershoot|NWIdth|PBASe|P CROss|PCTCROss|PDUty|
PE
AKHits|PERIod|PHAse|PK2Pk|P KPKJitter|
PKPKNoise|POVershoot|PTOP |PWIdth|QFACtor|
RISe|RMS|RMSJitter|RMSNoi se|SIGMA1|SIGMA2|
S
IGMA3|SIXSigmajit|SNRatio|ST Ddev|UNDEFINED| WAVEFORMS}
MEASUrement:MEAS<x>:TYPe?
Arguments
AMPlitude measures the amplitude of the selected waveform. In other words, it
measures the high value less the low value measured over the entire waveform or
gated region.
Amplitude = High - Low
AREa measures the voltage over time. The a rea is over the entire waveform or
gated region and is measured in volt-seconds. The area measured above the
ground is positive, while the area below ground is negative.
BURst measures the duration of a burst. The measurement is made over the entire
waveform or gated region.
CARea (cycle area) measures the voltage over time. In other words, it measures, in
volt-seconds, the area over the rst cycle in the waveform or the rst cycle in the
gated region. The area measured above the common reference point is positive,
while the area below the common reference point is negative.
2-396 DPO7000, DPO70000/B and DSA7000/B Series Programmer Manual

Table of Contents

Other manuals for Tektronix DSA70000/B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix DSA70000/B Series and is the answer not in the manual?

Tektronix DSA70000/B Series Specifications

General IconGeneral
BrandTektronix
ModelDSA70000/B Series
CategoryTest Equipment
LanguageEnglish

Related product manuals