Label
128 Manual m600 basic 2.6_01
7
Number/Sensor = 0
The set value of "0" describes the following situation: One pulse of the
photoelectric cell triggers as many prints as required. Printing is not
stopped until the photoelectric cell signals the end of the printing material.
Other
parameters
Fig. 7_220: Photoelectric cell pulse, e.g. caused by a paper edge
Number Sensor = x
If you enter a different value (maximum 999), the number of print cycles
per photoelectric cell signal can be precisely defined (in this example
"Number/Sensor 2").
Fig. 7_221: Photoelectric cell pulse, e.g. caused by printmarks
1 Print material, e. g. fan-fold
paper
4Distance after
2 Photoelectric cell 5 Distance before
3 Print head 6 Photoelectric cell pulse, e.g. caused by a
paper edge
NOTE
The setting "Number/Sensor 0" is ideal for printing end-
less material.
1 Print material, e. g. cartons 4 Distance after
2 Photoelectric cell 5 Distance before
3 Print head 6 Photoelectric cell pulse, e.g. caused by
printmarks
NOTE
This is the ideal setting if, for example, cartons have to
be printed several times for certainty.