Settings
54 Manual m600 basic 2.6_01
6
Input 2
Fig. 6_86: External input 2
Start sensor 2
The effect of selecting "Start sensor" is that the external input 2 is evalu-
ated for the trigger signal (start signal) for print head 2 instead of the pho-
toelectric cell on print head 1. The m600 basic reacts to the rising edge.
Deactivate m600 basic
Selecting "Deactivate m600 basic" means that input 2 can be used to de-
activate the m600 basic via an external signal (e. g. PLC). The function is
triggered with a falling edge. The red "Stop key" remains in operation.
Reset spit timer:
By selecting "Reset spit timer", the external input 2 can be used to reset
the automatic spitting process. The m600 basic reacts to the rising edge.
Input 3
Fig. 6_87: External input 3
Replace cartridge
By selecting "Replace cartridge", the external input 3 can be used to open
the menu for replacing the cartridge directly with an external signal (e. g.
PLC). The m600 basic reacts to the rising edge and switches immediately
to "Stop" mode.
6.2.2.2 Input 2
6.2.2.3 Input 3