Installation
30 Manual m600 basic 2.6_01
4
Connecting the
printer compo-
nents
Fig. 4_51: Connect the connector cable from the print head to the controller
4.7.1 Connecting the printer components
Do not connect the connector cable before the print heads, controller
and, if applicable, a pulse generator have been installed on the pro-
duction line.
Identify both ends of each print head cable using the enclosd cable
markers and insert strips.
Make sure that caps are fitted to all unused sockets on the controller.
Any damage resulting from IP65 caps which are not in place will not
be covered by the guarantee/ warranty.
Check that all union nuts are securely fastened on the connectors.
Otherwise there is risk of data communication errors.
Make sure that the connector cable is laid at a sufficient distance
from all sources of interference. Do not lay the cable parallel to any
frequency converters or servo-motor cables.
1 Conveyor belt 3 Pulse generator
2 Photoelectric cell 4 Back of the controller
ATTENTION
The device must be switched off when the print heads are
being installed. For further information on the positions of
the print heads, please refer to Chapter 4.3.1!
The following applies in general: The device must always
be switched off before you undertake any work of con-
necting or disconnecting.
1
3
4
2