Installation
Manual m600 basic 2.6_01 23
4
Remove the measuring object. If the function indicator (red LED)
does not light up without an object, continue turning the trimmer in
a clockwise direction until it lights up. This is point B.
NOTE
If the function indicator (red LED) lights up without an ob-
ject, the indicator must be switched off (turn trimmer
counterclockwise).
Then turn the trimmer in a clockwise direction again until
the function indicator lights up. This is point B.
Set the sensitivity to an average (point C) between point A and point
B. Once the sensitivity difference between point A and point B is half
a rotation, stable identification will be possible.
Set the D.ON/L.ON switch in dependency on whether the sensor
should be switched on or off for an object.
NOTE
After changing over the FINE/TURBO selector, sensitivity
must be readjusted.