NoteAction
xx1300000743
Refit the push button guard to the SMB cover.6
See Updating revolution counters
on page 542.
The revolution counters must be updated if the battery
has been disconnected.
7
DANGER
Make sure all safety requirements are met when
performing the first test run. These are further detailed
in the section DANGER - First test run may cause
injury or damage! on page 44.
8
3HAC044266-001 Revision: - 245
© Copyright 2013 ABB. All rights reserved.
4 Repair
4.4.4 Replacing the brake release unit
Continued