3.3.14 Inspecting, signal lamp (option)
Location of signal lamp
The signal lamp is located as shown in this figure.
Required equipment
NoteArt. no.Equipment, etc.
To be replaced if damage is detected.See Spare parts on
page 565.
Signal lamp kit
Content is defined in section Stand-
ard toolkit on page 559.
-Standard toolkit
These procedures include references
to the tools required.
Other tools and procedures may
be required. See references to
these procedures in the step-by-
step instructions below.
Inspecting, signal lamp
Use this procedure to inspect the function of the signal lamp.
NoteAction
Check that signal lamp is lit when motors are put in
operation ("MOTORS ON").
1
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working area.
2
Art. no. is specified in Required
equipment on page 136.
If the lamp is not lit, trace the fault by:
Checking whether the signal lamp is broken.
If so, replace it.
Checking cable connections.
Checking the cabling. Replace the cabling if a
fault is detected.
3
136 3HAC044266-001 Revision: -
© Copyright 2013 ABB. All rights reserved.
3 Maintenance