EasyManua.ls Logo

Adva FSP 3000 - Grounding and Power; General Power and Grounding Guidelines

Adva FSP 3000
375 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Power and Grounding Guidelines
Chapter 12
Grounding and Power
General Power and Grounding Guidelines 149
AC Power Source Requirements 150
DCPower Source Requirements 151
General Power and Grounding Guidelines
l Installation of the FSP 3000 C must be performed in compliance with your national and
local electrical codes.
o
International International Electrotechnical Commission (IEC) 60364, Part 1
through Part 7
o
United Kingdom (UK) British Standard BS 7671
o
United States of America (USA) United States National Electrical Code ®
(NEC) and United States National Fire Protection Association (NFPA 70®)
o
Canada Canadian Electrical Code, Part I, CSA C22.1 and CSA C22.4 No. 1 and
No. 2
l Each external power source must provide clean power to the installation site. If
necessary, install a power conditioner.
l Proper grounding is mandatory at the site to prevent damage to the equipment or
personal injury under dangerous fault conditions, such as lightning or over-voltages.
l FSP 3000 C shelves must be grounded. The shelves are suitable for installation as
part of the Common Bonding Network (CBN) or Isolated Bonding Network (IBN).
Follow national installation codes and regulations when making ground connections.
ELECTRIC VOLTAGEWARNING
When installing the equipment in a multi-unit rack assembly, the total
electrical/current loss through leakage should not exceed the maximum
allowable limit.
FSP3000 C Hardware Guide - R1.1 - Issue:A (12/09/2016) 149

Table of Contents

Related product manuals