Installing the FTM-4 in the SH4R
3. Grasp the handle while inserting the FTM into the appropriate slot.
4. Gently apply pressure to the faceplate while pushing the module into the slot.
5. Push on the faceplate to fully seat the module. The module is completely inserted
when its faceplate is flush with the faceplates of the adjacent modules and the shelf
panels.
6. When the FTM-2 is inserted completely, hand tighten the retaining screw to prevent
inadvertent dislodging.
7. Use a Torx T10 screwdriver to gently tighten the retaining screw as needed. Do not
overtighten.
8. Repeat this procedure for the other two FTM-2s in your SH12.
l Electrostatic Discharge Damage Prevention and Warning
l FTM-2
l SH12 Shelf
Installing the FTM-4 in the SH4R
This procedure assumes that:
l The shelf is properly grounded to the rack; and
l The shelf and module have been properly inspected.
1. Verify that you are properly grounded with an anti-static wrist strap or heel strap
connected to the grounded ESDjack.
2. Standing behind the SH4R, hold the FTM-4 upright with the faceplate toward you
(Mod LEDwill be in the bottom right).
3. Insert the FTM into the appropriate slot.
4. Gently apply pressure to the faceplate while pushing the module into the slot.
5. Push on the faceplate to fully seat the module. The module is completely inserted
when its faceplate is flush with the back plate of the SH4R.
6. When the FTM-4 is inserted completely, hand tighten the two retaining screws to
prevent inadvertent dislodging.
7. Use a Torx T10 screwdriver to gently tighten the retaining screws as needed. Do not
overtighten.
8. Repeat this procedure for the other FTM-4 in your SH4R.
l Electrostatic Discharge Damage Prevention and Warning
l FTM-4
l SH4R Shelf