Serial and Ethernet Cables
Compliance
l North America
o
ULlisted
o
CSAcertified
l Continental Europe
o
VDEcertified, European
l International
o
UL listed
o
VDE certified or harmonized
Female End Connector
Type
Left-angled connector plug
Coupler Type C19
The following table details the variants available for the CBL/AC/250/LA-C19 cable.
Cable Variant
Sales Item
Number
Notes
CBL/AC/250/LA-C19/EU 1036000687 Continental Europe market
CBL/AC/250/LA-C19/UK-10A
(Fuse value: 10A)
1036000688 United Kingdom market
CBL/AC/250/LA-C19/CH 1036000689 Switzerland market
CBL/AC/250/LA-C19/US 1036000690
United States (North America)
market
CBL/AC/250/LA-C19/AU 1036000691 Australia market
CBL/AC/250/LA-C19/IN 1036000692 India market
CBL/AC/250/LA-C19/JP 1036000693 Japan market
CBL/AC/250/LA-C19/C20 1036000684
IEC60320 C20 straight male
connector at other end
Serial and Ethernet Cables
Ethernet Cables 160
USB Cables 162
Ethernet Cables
To comply with EMC requirements networking connections must be made using shielded
Ethernet cables Cat5e or Cat6 cables, STP/FTP, exclusively.
Connect the LAN ports of the FSP 3000 C system only to intrabuilding or non-exposed
wiring or cabling. The intrabuilding cable must be shielded and the shield must be
grounded at both ends.
The following table details the Standard Cat5e and Cat6 Ethernet cables available from
ADVA Optical Networking.
160 FSP3000 C Hardware Guide - R1.1 - Issue:A (12/09/2016)