AM-S20H-2
Optical connector LC/PC
Interface type OMU
Protocols None, optical
Supported Fault Management (FM) LOS
Supported Performance Monitoring
(PM)
OPT, OPR, OPT TCA H/L, OPR TCA H/L
Monitor Interface
Number of monitor ports 2
Type of monitor interface
l Uni-directional
l Mon N-R: approx. 1% of EDFA input at N-R
l Mon C-T: approx. 1% of EDFA output at C-T
Optical connector LC/PC
Protocols None, optical
Network Interface
Number of network ports 1
Type of network interface Bi-directional: optical only
Optical connector LC/PC
Interface type OMU (interface without OSC)
Protocols OMU: none, optical
Supported Fault Management (FM) FM optical (OMU): LOS-P or LOS
Supported Performance Monitoring
(PM)
PM optical (OMU): OPT, OPR, OPT TCA
H/L, OPR TCA H/L, SES-P, UAS-P
68 FSP3000 C Hardware Guide - R1.1 - Issue:A (12/09/2016)