EasyManua.ls Logo

Adva FSP 3000 - Electrostatic Discharge Damage Prevention and Warning

Adva FSP 3000
375 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrostatic Discharge Damage Prevention and Warning
Risk Details
Fire due to
Component
Overheating
l Keep power inlet terminals free from dust. Keep the
protective cover fitted on the terminal block of the DC-
input power supply modules.
l Ensure that the air inlets and outlets have enough
clearance to promote airflow for cooling. Always have
sufficient air ventilation during operation
l The shelves must never be operated with open or empty
slots. Slots not in use must be filled with slot covers to
maintain proper cooling for all other modules.
l Do not operate a shelf for extended periods without having
an air filter pad fitted in the air filter unit.
l If you do not have slot covers and air filter pads installed,
dust and dirt can enter the shelf and block the air inlets
and outlets. Blocked air inlets and outlets, as well as
uncovered shelf slots, lead to insufficient airflow for
cooling of modules and considerably increase in fire risk.
Skin Burns
l Module components get hot during operation. Hot
components can burn skin. Allow a module to cool before
touching it.
Electromagnetic
Interference
l The shelves must never be operated with open or empty
slots. Failure to properly seal the shelf will result in
electromagnetic interference.
l The intrabuilding cables must be shielded and the shield
must be grounded at both ends.
l Definition of Safety Warning Levels
l Installation Safety Guidelines and Warnings
l Laser and LED Safety Guidelines and Warnings
l Electrical Safety Guidelines and Warnings
Electrostatic Discharge Damage Prevention
and Warning
If FSP 3000 C equipment can be damaged by electrostatic discharge (ESD)if it is
improperly handled during unpacking, installation, removal, storage, or shipment. This
damage can result in complete or intermittent failures.
To stop static electricity from damaging electronic equipment, an ESD safe work area is
essential for service personnel. In addition, proper ESD protection is required whenever
you handle FSP 3000 C products.
318 FSP3000 C Hardware Guide - R1.1 - Issue:A (12/09/2016)

Table of Contents