Eye Safety Guidelines
l Always wear the appropriate laser safety glasses when required. Be sure that they
meet national laser safety regulations and are matched to the lasers used within your
environment.
l Do not look into unterminated ports or at fibers that connect to unknown sources.
Laser infrared radiation, which is not visible to the naked eye, may be emitted from
unterminated receptacles of an optical module or an optical fiber connector if the
associated fiber-optic transmitter has been powered up.
l Do not examine unterminated optical ports with optical instruments.
l Viewing the laser output with certain optical instruments (for example, eye loupes,
magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard.
Before using an optical instrument to inspect a connector, use a power meter to
confirm that the fiber is not transmitting optical energy.
l Laser radiation may be emitted from optical testing equipment into the optical fibers.
Take the necessary precautions.
l Cap unused ports and connectors to prevent accidental exposure to laser emission.
l Remove the protective caps or blind plugs from the client and network output channel
(Tx) connectors only when necessary for installation and maintenance purposes.
Failure to do so can cause permanent eye or skin damage and can also lead to
blindness.
l Avoid direct exposure to the beam.
l Do not wear contact lenses while working with optical fiber cables.
l Do not connect or disconnect fiber-optic cables at eye level.
LASERRADIATIONWARNING
l Use of controls or adjustments or performance of procedures other
than those specified in the FSP 3000 C documentation may result in
hazardous radiation exposure.
l There is exposure to hazardous laser radiation when the protective
housing is open and interlocks are defeated. Do not remove the
covers. There are no serviceable parts inside the device.
l Even for extremely short durations of exposing optical power levels,
permanent eye damage or blindness can result.
l High intensity and invisible light is emitted from the optical output
receptacles of amplifier modules. Ensure that all connectors are
terminated properly before setting the amplifier's Admin state to "In
Service".