The DMM tab page contains the following parameters:
Type
Use the drop-down menu to select the relevant operation type (On-demand
operation or Proactive operation).
Rate
Use the drop-down menu to select the rate at which DMM frames are
transmitted.
Frames to send
Allows you to specify the number of frames to transmit.
Delay threshold
Allows you to specify a delay threshold that is used when a DMM test is
active. If the delay meets or exceeds that threshold, the user is alerted.
Optional TLV
Use the drop-down menu to select a TLV type, if relevant. The possible types
are: Data TLV and Test TLV. If you select one of the TLV types, fields for
specifying the ID will appear.
Length
Only available if a Data TLV type has been selected. Allows you to specify
the length of the TLV.
Value
Only available if a Data TLV type has been selected. Allows you to specify
the value of the TLV. Note that for the Data TLV type, this field is an entry
field where you open an editor and type the value.
ID
Only available if a Test TLV type has been selected. Allows you to specify
the value of the ID.
LMM tab page
The LMM tab page contains the following parameters:
Rate
Use the drop-down menu to select the rate at which LMM frames are
transmitted.
Frames to send
Allows you to specify the number of frames to transmit.
Loss threshold
Allows you to specify a loss threshold that is used when an LMM test is
active. If the loss ratio meets or exceeds that threshold, the user is alerted.
SLM tab page
The SLM tab page contains the following parameters:
Rate
Use the drop-down menu to select the rate at which SLM frames are
transmitted.
Frames to send
Allows you to specify the number of frames to transmit.
Loss threshold
Allows you to specify a loss threshold that is used when an SLM test is active.
If the loss ratio meets or exceeds that threshold, the user is alerted.
Ethernet Applications Ethernet Setup and Status
MT1000A Network Master Pro Page 215