Version 6.2 385 February 2011
SIP User's Manual 5. EMS-Based Management
5.7.2 Configuring EMS to Operate with a Pre-configured SNMPv3
System
The procedure below describes how to configure the device with a pre-configured
SNMPv3.
¾ To configure EMS to operate with a pre-configured SNMPv3 system:
1. In the MG Tree, select the required Region to which the device belongs, and then
right-click the device.
2. From the shortcut menu, choose Details; the 'MG Information' screen appears.
Figure 5-12: MG Information Screen
3. Select the SNMPv3 option, configure the SNMP fields, and then click OK.
4. Open the 'SNMPv3 Users' screen (Navigation pane > System > Management >
SNMP Frame > SNMPv3 Users tab).
5. From the SNMPv3 Users tab's drop-down list, choose Unit value; the 'SNMPv3
Users' table is refreshed with the values that you entered in Step 3.
6. Click the Save button; the EMS and the device are now synchronized.