Version 6.2  679  February 2011 
SIP User's Manual   12. Configuration Parameters Reference 
 
Parameter  Description 
Web: RADIUS VSA Vendor ID 
[RadiusVSAVendorID] 
Defines the vendor ID that the device accepts when parsing a 
RADIUS response packet. 
The valid range is 0 to 0xFFFFFFFF. The default value is 5003. 
Web: RADIUS VSA Access 
Level Attribute 
[RadiusVSAAccessAttribute] 
Defines the code that indicates the access level attribute in the 
Vendor Specific Attributes (VSA) section of the received RADIUS 
packet. 
The valid range is 0 to 255. The default value is 35. 
 
 
12.6  SNMP Parameters 
The SNMP parameters are described in the table below. 
Table  12-23: SNMP Parameters 
Parameter  Description 
Web: Enable SNMP 
[DisableSNMP] 
Determines whether SNMP is enabled. 
  [0] Enable = SNMP is enabled (default). 
  [1] Disable = SNMP is disabled and no traps are sent. 
[SNMPPort] 
The device's local UDP port used for SNMP Get/Set 
commands. 
The range is 100 to 3999. The default port is 161. 
Note: For this parameter to take effect, a device reset is 
required. 
[SNMPTrustedMGR_x] 
Defines up to five IP addresses of remote trusted SNMP 
managers from which the SNMP agent accepts and processes 
SNMP Get and Set requests. 
Notes: 
  By default, the SNMP agent accepts SNMP Get and Set 
requests from any IP address, as long as the correct 
community string is used in the request. Security can be 
enhanced by using Trusted Managers, which is an IP 
address from which the SNMP agent accepts and 
processes SNMP requests. 
  If no values are assigned to these parameters any 
manager can access the device. 
  Trusted managers can work with all community strings. 
[ChassisPhysicalAlias] 
This object is an 'alias' name for the physical entity as 
specified by a network manager, and provides a non-volatile 
'handle' for the physical entity. 
The valid range is a string of up to 255 characters. 
[ChassisPhysicalAssetID] 
This object is a user-assigned asset tracking identifier for the 
device's chassis as specified by an EMS, and provides non-
volatile storage of this information. 