EasyManua.ls Logo

AudioCodes Mediant 800 MSBG - SNMP Parameters

AudioCodes Mediant 800 MSBG
890 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Version 6.2 679 February 2011
SIP User's Manual 12. Configuration Parameters Reference
Parameter Description
Web: RADIUS VSA Vendor ID
[RadiusVSAVendorID]
Defines the vendor ID that the device accepts when parsing a
RADIUS response packet.
The valid range is 0 to 0xFFFFFFFF. The default value is 5003.
Web: RADIUS VSA Access
Level Attribute
[RadiusVSAAccessAttribute]
Defines the code that indicates the access level attribute in the
Vendor Specific Attributes (VSA) section of the received RADIUS
packet.
The valid range is 0 to 255. The default value is 35.
12.6 SNMP Parameters
The SNMP parameters are described in the table below.
Table 12-23: SNMP Parameters
Parameter Description
Web: Enable SNMP
[DisableSNMP]
Determines whether SNMP is enabled.
[0] Enable = SNMP is enabled (default).
[1] Disable = SNMP is disabled and no traps are sent.
[SNMPPort]
The device's local UDP port used for SNMP Get/Set
commands.
The range is 100 to 3999. The default port is 161.
Note: For this parameter to take effect, a device reset is
required.
[SNMPTrustedMGR_x]
Defines up to five IP addresses of remote trusted SNMP
managers from which the SNMP agent accepts and processes
SNMP Get and Set requests.
Notes:
By default, the SNMP agent accepts SNMP Get and Set
requests from any IP address, as long as the correct
community string is used in the request. Security can be
enhanced by using Trusted Managers, which is an IP
address from which the SNMP agent accepts and
processes SNMP requests.
If no values are assigned to these parameters any
manager can access the device.
Trusted managers can work with all community strings.
[ChassisPhysicalAlias]
This object is an 'alias' name for the physical entity as
specified by a network manager, and provides a non-volatile
'handle' for the physical entity.
The valid range is a string of up to 255 characters.
[ChassisPhysicalAssetID]
This object is a user-assigned asset tracking identifier for the
device's chassis as specified by an EMS, and provides non-
volatile storage of this information.
The valid range is a string of up to 255 characters.

Table of Contents

Other manuals for AudioCodes Mediant 800 MSBG

Related product manuals