SIP User's Manual 666 Document #: LTRT-12804
Mediant 800 MSBG
Parameter Description
[0] = Lifeline is activated upon power failure (default).
[1] = Lifeline is activated upon power failure or when the link is down
(physically disconnected).
[2] = Lifeline is activated upon power failure, when the link is down, or
upon network failure (logical link disconnected).
Notes:
For this parameter to take effect, a device reset is required.
This parameter is applicable only to FXS interfaces.
To enable Lifeline switching on network failure, the LAN watch dog
must be activated (i.e., set the parameter EnableLANWatchDog to 1).
For a detailed description on cabling the device for Lifeline, refer to
the Installation Manual.
Web: Delay After Reset
[sec]
[GWAppDelayTime]
Defines the time interval (in seconds) that the device's operation is
delayed after a reset.
The valid range is 0 to 45. The default value is 7 seconds.
Note: This feature helps overcome connection problems caused by
some LAN routers or IP configuration parameters' modifications by a
DHCP server.
12.3.2 Syslog, CDR and Debug Parameters
The Syslog, CDR and debug parameters are described in the table below.
Table 12-13: Syslog, CDR and Debug Parameters
Parameter Description
Web: Enable Syslog
EMS: Syslog enable
[EnableSyslog]
Sends the logs and error message generated by the device to the
Syslog server.
[0] Disable = Logs and errors are not sent to the Syslog server
(default).
[1] Enable = Enables the Syslog server.
Notes:
If you enable Syslog, you must enter an IP address of the Syslog
server (using the SyslogServerIP parameter).
Syslog messages may increase the network traffic.
To configure Syslog SIP message logging levels, use the
GwDebugLevel parameter.
For information on the Syslog, refer to the Product Reference
Manual.
By default, logs are also sent to the RS-232 serial port. For
information on establishing a serial communications link with the
device, refer to the Installation Manual.