SIP User's Manual 664 Document #: LTRT-12804
Mediant 800 MSBG
Parameter Description
[WelcomeMessage]
This ini file table parameter configures the Welcome message that
appears after a Web interface login. The format of this parameter is as
follows:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index = WelcomeMessage_Text
[\WelcomeMessage]
For Example:
FORMAT WelcomeMessage_Index = WelcomeMessage_Text
WelcomeMessage 1 = "**********************************" ;
WelcomeMessage 2 = "********* This is a Welcome message ***" ;
WelcomeMessage 3 = "**********************************" ;
Notes:
Each index represents a line of text in the Welcome message box.
Up to 20 indices can be defined.
The configured text message must be enclosed in double quotation
marks (i.e., "...").
If this parameter is not configured, no Welcome message is
displayed.
For a description on using ini file table parameters, see ''Configuring
ini File Table Parameters'' on page 368.
12.2.3 Telnet Parameters
The Telnet parameters are described in the table below. Note: Telnet is currently supported
only for debugging from the LAN interface.
Table 12-11: Telnet Parameters
Parameter Description
Web: Embedded Telnet Server
EMS: Server Enable
[TelnetServerEnable]
Enables or disables the device's embedded Telnet server. Telnet is
disabled by default for security.
[0] Disable (default)
[1] Enable Unsecured
[2] Enable Secured (SSL)
Note: Only the primary Web User Account (which has Security
Administration access level) can access the device using Telnet
(see ''Configuring Web User Accounts'' on page 73).
Web: Telnet Server TCP Port
EMS: Server Port
[TelnetServerPort]
Defines the port number for the embedded Telnet server.
The valid range is all valid port numbers. The default port is 23.
Web: Telnet Server Idle
Timeout
EMS: Server Idle Disconnect
[TelnetServerIdleDisconnect]
Defines the timeout (in minutes) for disconnection of an idle Telnet
session. When set to zero, idle sessions are not disconnected.
The valid range is any value. The default value is 0.
Note: For this parameter to take effect, a device reset is required.
Web/EMS: WAN Telnet Server
Port
[WanMgmtTelnetPort]
Defines the WAN management port number for the embedded
Telnet server.
The valid range is all valid port numbers. The default port is 23.