EasyManua.ls Logo

AudioCodes Mediant 800 MSBG - Page 736

AudioCodes Mediant 800 MSBG
890 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SIP User's Manual 736 Document #: LTRT-12804
Mediant 800 MSBG
Parameter Description
Web: Fax/Modem Bypass
Packing Factor
EMS: Packetization Period
[FaxModemBypassM]
Number of (20 msec) coder payloads that are used to generate a
fax/modem bypass packet.
The valid range is 1, 2, or 3 coder payloads. The default value is
1 coder payload.
[FaxModemNTEMode]
Determines whether the device sends RFC 2833 ANS/ANSam
events upon detection of fax and/or modem Answer tones (i.e.,
CED tone).
[0] = Disabled (default).
[1] = Enabled.
Note: This parameter is applicable only when the fax or modem
transport type is set to bypass or Transparent-with-Events.
Web/EMS: Fax Bypass Payload
Type
[FaxBypassPayloadType]
Determines the fax bypass RTP dynamic payload type.
The valid range is 96 to 120. The default value is 102.
EMS: Modem Bypass Payload
Type
[ModemBypassPayloadType]
Modem Bypass dynamic payload type.
The range is 0-127. The default value is 103.
EMS: Relay Volume (dBm)
[FaxModemRelayVolume]
Determines the fax gain control.
The range is -18 to -3, corresponding to -18 dBm to -3 dBm in 1-
dB steps. The default is -6 dBm fax gain control.
Web/EMS: Fax Bypass Output
Gain
[FaxBypassOutputGain]
Defines the fax bypass output gain control.
The range is -31 to +31 dB, in 1-dB steps. The default is 0 (i.e.,
no gain).
Web/EMS: Modem Bypass
Output Gain
[ModemBypassOutputGain]
Defines the modem bypass output gain control.
The range is -31 dB to +31 dB, in 1-dB steps. The default is 0
(i.e., no gain).
EMS: NTE Max Duration
[NTEMaxDuration]
Maximum time for sending Named Telephony Events (NTEs) to
the IP side regardless of the time range when the TDM signal is
detected.
The range is -1 to 200,000,000 msec (i.e., 55 hours). The default
is -1 (i.e., NTE stops only upon detection of an End event).
EMS: Basic Packet Interval
[FaxModemBypassBasicRTPP
acketInterval]
Determines the basic frame size that is used during fax/modem
bypass sessions.
[0] = Determined internally (default)
[1] = 5 msec (not recommended)
[2] = 10 msec
[3] = 20 msec
Note: When set to 5 msec (1), the maximum number of
simultaneous channels supported is 120.
EMS: Dynamic Jitter Buffer
Minimal Delay (dB)
[FaxModemBypasDJBufMinDel
ay]
Determines the Jitter Buffer delay (in milliseconds) during fax and
modem bypass session.
The range is 0 to 150 msec. The default is 40.

Table of Contents