SIP User's Manual 880 Document #: LTRT-12804
Mediant 800 MSBG
Parameter Description
Pattern Detection Parameters
Note: For an overview on the pattern detector feature for TDM tunneling, see DSP Pattern Detector
on page 650.
Web: Enable Pattern Detector
[EnablePatternDetector]
Enables or disables the activation of the Pattern Detector (PD).
Valid options include:
[0] Disable = Disable (default)
[1] Enable = Enable
[PDPattern]
Defines the patterns that can be detected by the Pattern Detector.
The valid range is 0 to 0xFF.
Note: For this parameter to take effect, a device reset is required.
[PDThreshold]
Defines the number of consecutive patterns to trigger the pattern
detection event.
The valid range is 0 to 31. The default is 5.
Note: For this parameter to take effect, a device reset is required.