EasyManuals Logo

Dell PowerConnect 5324 Command Line Interface Reference Manual

Dell PowerConnect 5324
388 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #151 background imageLoading...
Page #151 background image
IGMP Snooping Commands 151
Syntax
ip igmp snooping host-time-out
time-out
no ip igmp snooping host-time-out
time-out
—Host timeout in seconds. (Range: 1 - 2147483647)
Default Configuration
The default host-time-out is 260 seconds.
Command Mode
Interface Configuration (VLAN) mode
User Guidelines
The timeout should be at least greater than 2*query_interval+max_response_time of the
IGMP router.
Example
The following example configures the host timeout to 300 seconds.
ip igmp snooping mrouter-time-out
The
ip igmp snooping mrouter-time-out
Interface Configuration mode command configures the
mrouter-time-out. The
mrouter-time-out
command is used for setting the aging-out time after
multicast router ports are automatically learned. To configure the default mrouter-time-out, use
the
no
form of this command.
Syntax
ip igmp snooping mrouter-time-out
time-out
no ip igmp snooping mrouter-time-out
time-out
—mrouter timeout in seconds (Range: 1 - 2147483647)
Default Configuration
The default value is 300 seconds.
Command Mode
Interface Configuration (VLAN) mode
Console (config)# interface vlan 2
Console (config-if)# ip igmp snooping host-time-out 300

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2