346 VLAN Commands
www.dell.com | support.dell.com
Command Mode
Interface configuration (Ethernet, port-channel) mode
User Guidelines
This command has the following consequences: incoming untagged frames are assigned to
this VLAN and outgoing traffic in this VLAN on this port is sent untagged (despite the
normal situation where traffic sent from a trunk-mode port is all tagged).
Example
The following example shows how to configure the PVID for g8, when the interface is in general
mode.
switchport general ingress-filtering disable
The
switchport general ingress-filtering disable
Interface Configuration mode command disables
port ingress filtering. To enable ingress filtering on a port, use the
no
form of this command.
Syntax
switchport general ingress-filtering
disable
no switchport general ingress-filtering
disable
Default Configuration
Ingress filtering is enabled.
Command Mode
Interface Configuration (Ethernet, port-channel) mode
User Guidelines
There are no user guidelines for this command.
Example
The following example shows how to enables port ingress filtering on g8.
Console (config)# interface ethernet g8
Console (config-if)# switchport general pvid 234
Console (config)# interface ethernet g8
Console (config-if)# switchport general ingress-filtering disable

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2

Related product manuals