304 Syslog Commands
www.dell.com | support.dell.com
port
—Port number for syslog messages. If unspecified, the port number defaults to 514.
(Range: 1 - 65535)
severity
level
—Limits the logging of messages to the syslog servers to a specified level:
emergencies
,
alerts
,
critical
,
errors
,
warnings
,
notifications
,
informational
and
debugging
. If unspecified, the default level is
errors
.
facility
—The facility that is indicated in the message. Can be one of the following values:
local0, local1, local2, local3, local4, local5, local 6, local7
. If unspecified, the port
number defaults to
local7
.
text
—Syslog server description, which can be up to 64 characters.
Default Configuration
As described in the field descriptions.
Command Mode
Global Configuration mode
User Guidelines
Multiple syslog servers can be used.
If no specific severity level is specified, the global values apply to each server.
Example
The following example configures messages with a "critical" severity level so that they are logged to
a syslog server with an IP address 10.1.1.1.
logging console
The
logging console
Global Configuration mode command limits messages logged to the console
based on severity. To disable logging to the console terminal, use the
no
form of this command.
Syntax
logging console
level
no logging console
level
—Limits the logging of messages displayed on the console to a specified level:
emergencies, alerts
,
critical
,
errors, warnings
,
notifications, informational, debugging.
Default Configuration
The default is
informational
.
Console (config)# logging 10.1.1.1 severity critical

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2

Related product manuals