242 SNMP Commands
www.dell.com | support.dell.com
2
Map the internal security-name for SNMPv1 and SNMPv2 security models to an internal
group-name.
3
Map the internal group-name for SNMPv1 and SNMPv2 security models to
view-name
(read-view and notify-view always, and for
rw
for write-view also)
You can use the
group-name
to restrict the access rights of a community string.
By specifying the
group-name
parameter the software:
1
Generates an internal security-name.
2
Map the internal security-name for SNMPv1 and SNMPv2 security models to the
group-
name
.
Examples
The following example sets up the community access string "public" to permit administrative
access to SNMP protocol, at an administrative station with the IP address 192.168.1.20.
snmp-server view
To create or update a view entry, use the
snmp-server view
global configuration command. To
remove the specified Simple Network Management Protocol (SNMP) server view entry, use the
no
form of this command.
Syntax
snmp-server view
view-name
oid-tree
{
included
|
excluded
}
no snmp-server view
view-name
[
oid-tree
]
view-name
— Label for the view record that you are updating or creating. The name is
used to reference the record. (Range:1 - 30 chars)
oid-tree
— Object identifier of the ASN.1 subtree to be included or excluded from the
view. To identify the subtree, specify a text string consisting of numbers, such as
1.3.6.2.4
,
or a word, such as
system
. Replace a single subidentifier with the asterisk (*) wildcard to
specify a subtree family; for example 1.3.*.4.
included
— The view type is included.
excluded
— The view type is excluded.
Default Setting
"Default" and "DefaultSuper" views exists.
Command Mode
Global configuration
Console (config)# snmp-server community public su 192.168.1.20

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2