Page #212 background image
212 QoS Commands
www.dell.com | support.dell.com
Example
The following example assigns WRR weights to egress queues.
priority-queue out num-of-queues
The
priority-queue out num-of-queues
Global Configuration mode command enables the egress
queues to be expedite queues. Use the
no
form of this command to return to the default values.
Syntax
priority-queue out num-of-queues
number-of-queues
no priority-queue out
num-of-queues
number-of-queues
—Assign the number of queues to be expedite queues. The expedite
queues would be the queues with higher indexes. (Range: 1 - 4)
Default Configuration
All queues are expedite queues.
Command Mode
Global Configuration mode
User Guidelines
When configuring the
priority-queue out num-of-queues
command, the weighted round
robin (WRR) weight ratios are affected because there are fewer queues participating in WRR.
Queue 4 is taken as the highest index queue. Queue 3 is taken as the next highest queue. If
two priority queues are selected then queue 4 and 3 will be used. Leaving queue 2 and 1 for
WRR.
Console(config)# priority-queue num-of-queues 1
Console(config)# interface ethernet g1
Console(config-if)# wrr-queue bandwidth 20 30 50
Console(config)# priority-queue num-of-queues 0
Console(config)# interface ethernet g3
Console(config-if)# wrr-queue bandwidth 20 30 50 10

Table of Contents

Other manuals for Dell PowerConnect 5324

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerConnect 5324 and is the answer not in the manual?

Dell PowerConnect 5324 Specifications

General IconGeneral
Switching Capacity48 Gbps
VLAN SupportYes
Rack MountableYes
Device TypeSwitch
MAC Address Table Size8K entries
RAM64 MB
Flash Memory8 MB
Power DeviceInternal power supply
Voltage RequiredAC 120/230 V (50/60 Hz)
Jumbo Frame SupportYes
Ports24 x 10/100/1000 + 2 x SFP
ManagementWeb-based, SNMP, CLI
Enclosure TypeRack-mountable
Routing ProtocolStatic IP routing
Remote Management ProtocolSNMP 1, 2, 3
FeaturesFlow control, auto-negotiation, port mirroring, Quality of Service (QoS)
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Operating Temperature0 °C to 45 °C
Storage Temperature-20 °C to 70 °C
Humidity5% to 95% (non-condensing)
LayerLayer 2

Related product manuals