Configuring the ECN330-switch
130 1553-KDU 137 365 Uen D 2006-06-16
Secret Text String – Encryption key used to authenticate logon
access for client. Do not use blank spaces in the string. (Maximum
length: 20 characters)
Number of Server Transmits – Number of times the ECN330-
switch tries to authenticate logon access through the authentication
server. (Range: 1-30; Default: 2)
Timeout for a reply – The number of seconds the ECN330-switch
waits for a reply from the RADIUS server before it resends the
request. (Range: 1-65535; Default: 5)
TACACS Settings
Server IP Address – Address of the TACACS+ server. (Default:
10.11.12.13)
Server Port Number – Network (TCP) port of TACACS+ server
used for authentication messages. (Range: 1-65535; Default: 49)
Secret Text String – Encryption key used to authenticate logon
access for client. Do not use blank spaces in the string. (Maximum
length: 20 characters)
Note: The local ECN330-switch user database has to be set up by manually
entering user names and passwords using the CLI. (See “username” on
page 633.)