Configuring the ECN330-switch
266 1553-KDU 137 365 Uen D 2006-06-16
State – Shows the following EAPS states:
Master Node
Idle – The EAPS domain has been enabled, but the configuration is
not complete.
Init – The EAPS domain has started but has not yet determined the
status of the ring.
Complete – The ring is in the COMPLETE state for this EAPS
domain.
Failed – There is a break in the ring for this EAPS domain.
Transit Node
Idle – The EAPS domain has been enabled, but the configuration is
not complete.
Link-Up – The EAPS domain is running, and both of its ports are up
and in the FORWARDING state.
Link-Down – This EAPS domain is running, but one or both of its
ports are down.
Preforwarding – This EAPS domain is running, but the new link port
is temporarily blocked. When the state changes from link-down to
link-up on a transit node, the new link port is temporarily blocked
until the master node enters the Complete state. This transition time
is known as the preforwarding time.
Mode – Shows if the ECN330-switch is a master or transit node.
Status – Shows if the specified domain is enabled.
Hello Timer (secs) – The interval at which the master node sends
health-check packets on the domain ring.
Fail Timer (secs) – The time the master node waits for a health-check
packet before declaring a break in the ring.
Preforwarding Timer (secs) – The interval a transit node waits before
transitioning from BLOCKED state to forwarding state.
Primary Port – Shows the primary port on this node.
Primary Port Status – Shows the port connection status or link status
(Up, Down, Block).