Configuring the ECN330-switch
322 1553-KDU 137 365 Uen D 2006-06-16
6.13.3 Displaying MPLS Virtual Channel Settings
Use the VPN Information page to display the L2MPLS tunnel settings.
Field Attributes
MPLS VLAN Information
Client Interface – A VLAN configured to operate as an L2MPLS tunnel.
This VLAN is connected to the client interface on the edge switch of the
service provider’s network.
VC State – The status of the Virtual Channel can be one of the
following:
UP – The VC can carry traffic between the two endpoints.
DOWN – The VC is not ready to carry traffic between the two
endpoints. When no input and output labels are configured, the VC
state is down
ADMIN DOWN—The VC has been administratively disabled.
Local VC Label – This label determines the egress interface of a packet
arriving from the MPLS backbone.
Remote VC Label – This label is used by a remote peer switch.
MPLS Uplink Port Information
Uplink Interface – The uplink port connected to the client interface.
Tunnel Label The MPLS tunnel label that is used by switches within
the MPLS core network to establish a path from the entry point to the
exit point.
VC Label – The Virtual Channel identifier that is used to map traffic to
a specific customer port on the edge switches at the boundaries of the
MPLS network.
Next Hop IP – The IP address of the next hop across the MPLS
network.
DA MAC – The MAC address of the remote switch’s interface at the
other end of the VC. The default DA-MAC of MPLS uplink port is 00-00-
00-00-00-00.