Command Line Interface
8371553-KDU 137 365 Uen D 2006-06-16
Table 87 show eaps - summary display description
Field Description
EAPS Enabled Shows whether EAPS is enabled on the ECN330-
switch.
Number of EAPS
instances
Shows the number of EAPS instances configured on
the ECN330-switch.
Domain Displays the name of each domain followed by a brief
list of status information
State Shows the following EAPS states:
Master Node
Idle – The EAPS domain has been enabled, but the
configuration is not complete.
Init – The EAPS domain has started but has not yet
determined the status of the ring.
Complete – The ring is in the COMPLETE state for
this EAPS domain.
Failed – There is a break in the ring for this EAPS
domain.
Transit Node
Idle – The EAPS domain has been enabled, but the
configuration is not complete.
Link-Up – The EAPS domain is running, and both of
its ports are up and in the FORWARDING state.
Link-Down – This EAPS domain is running, but one
or both of its ports are down.
Preforwarding – This EAPS domain is running, and
both of its ports are up, but the new link port is in a
temporary BLOCKED state.
Mode Shows if the ECN330-switch is a master or transit
node.
En Shows if the specified domain is enabled.