The MIC contains two logical PICs, numbered PIC 0 through PIC 1 in the CLI. Each logical
PIC contains 10 ports numbered 0 through 9.
The following sample CLI output displays a 20-port Gigabit Ethernet MIC with SFP — 3D
20x 1GE(LAN) SFP — installed in slot 0 of an MPC in slot 3.
user@host> show chassis hardware
...
FPC 3 REV 28 750-031090 YH8181 MPC Type 2 3D EQ
CPU REV 06 711-030884 YH9437 MPC PMB 2G
MIC 0 REV 22 750-028392 YD0439 3D 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 01 740-011613 PCE14D5 SFP-SX
Xcvr 1 REV 01 740-011782 P9C280T SFP-SX
Xcvr 2 REV 01 740-011782 P9C2512 SFP-SX
Xcvr 3 REV 02 740-011613 AM0951SFF3Z SFP-SX
Xcvr 4 REV 02 740-011613 AM0951SFF33 SFP-SX
Xcvr 5 REV 02 740-011613 AM0951SFF3Y SFP-SX
Xcvr 6 REV 02 740-011613 AM0951SFF4B SFP-SX
Xcvr 7 REV 01 740-011613 E08H01273 SFP-SX
Xcvr 8 REV 02 740-011613 AM0951SFFWK SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 01 740-011613 E08H00516 SFP-SX
Xcvr 1 REV 01 740-011613 E08G03648 SFP-SX
Xcvr 2 REV 01 740-011613 E08H00514 SFP-SX
...
The show chassis hardware command output shows an MPC (MPC Type 2 3D EQ) installed
in slot 3 and is shown as FPC 3 in the CLI. The MIC’s two logical PICs — 10x 1GE(LAN) SFP
— are shown as PIC 0 and PIC 1.
The show interfaces terse command output displays the Gigabit Ethernet interfaces, that
correspond to the 20 ports located on the MIC.
user@host>show interfaces terse ge-3*
Interface Admin Link Proto Local Remote
ge-3/0/0 up down
ge-3/0/1 up down
ge-3/0/2 up down
ge-3/0/3 up up
ge-3/0/4 up up
ge-3/0/5 up up
ge-3/0/6 up up
ge-3/0/7 up up
ge-3/0/8 up up
ge-3/0/9 up down
ge-3/1/0 up up
ge-3/1/1 up up
ge-3/1/2 up up
ge-3/1/3 up down
ge-3/1/4 up down
ge-3/1/5 up down
ge-3/1/6 up down
ge-3/1/7 up down
ge-3/1/8 up down
ge-3/1/9 up down
79Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Line Card Components and Descriptions