Press the AS MSC offline/online button until the LED light turns green.
•
Issue the following CLI command:
user@host> request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the CLI Explorer.
The normal functioning status LED confirms that the AS MSC is online. You can also
verify correct AS MSC functioning by issuing the show chassis fpc pic-status.
Figure 156: Installing an AS MSC
See Also MX480 Application Services Modular Storage Card Description on page 96•